LaMotte - LaMotte - LaMotte -  - Calibration Standard (4.0 Ppt) 120 Ml, LaMotte (6004-J)
TEL: 1-520-213-8418  
 

 
Categories
Salt Cell Replacements (Electrodes) ->

Salt Water Chlorinators ->

Salt Water Chlorinators -Spas

Salt Chlorinators-Commericial ->

Accessories-Pool/ Spa/ Landscaping

Automatic Pool Cleaners

Chemical Controllers (Automation) ->

Chemicals (ALL) ->

Electrical / Electronic / Timers ->

Maintenance Equipment

Miscellaneous

Parts Section- Salt Chlorinators ->

Parts For All Pool Equipment ->

Plumbing Supplies, O-Rings, PVC, ETC ->

Pumps, Swimming Pool

Pump Motors

Salt

Test Equipment & Reagents ->
|__Phosphate Test Kits
|__Test Equip & Meter Parts->
|__Test Kits
|__Test Meters->
|__Test Reagents->
    |__Goldline / Aqua Rite
    |__LaMotte
    |__Taylor Technologies
    |__Test Reagents-Misc.
|__Test Strips

Tools for Installation

Used Or Reconditioned Products

View All Products->

All Products sorted by Categories ->

All Products sorted by Manufacturers ->
Specials
Pristine Salt Chlorinator (100 amp) PRI-100, Reverse Polarity
Pristine Salt Chlorinator (100 amp) PRI-100, Reverse Polarity
$3,395.73
$1,995.00
View All Discount Products
Manufacturers
Notifications
NotificationsNotify me of updates to Calibration Standard (4.0 Ppt) 120 Ml, LaMotte (6004-J)
New Products
SGS Salt Cell Housing (2")Universal (2" x 5-1/2" oc) * Generic
SGS Salt Cell Housing (2")Universal (2" x 5-1/2" oc) * Generic
$69.00
View Latest Additions
Featured Links
Domain Registration and Hosting
Gereral Products for Sale
How to Incorporate Your Business
Swimming Pool Supplies
Who's Online
There currently are 58 guests and 
20 members online.
Events Calendar


Calibration Standard (4.0 Ppt) 120 Ml, LaMotte (6004-J)
[391-6004J]

$10.66

 
box_bg_l.gif


Calibration Standard (4.0 Ppt) 120 Ml, LaMotte (6004-J)

  • For calibrating Meter 26094-34 (Salt Meter)
  • Part Number: 6004 J

PRECONDITIONING

Remove the electrode cap. Soak the electrodes for a few minutes in alcohol to remove oils.

CALIBRATION

The Salt Tester should be calibrated before use. The tester should be calibrated on a regular basis. Once a week is recommended.

NOTE: 1 part per thousand (ppt) = 1000 parts per million (ppm)

Example: 3.1 ppt = 3,100 ppm

CALIBRATION PROCEDURE

1. Open the battery compartment lid (end with the lanyard loop). The two white buttons are Increment (INC) and Decrement (DEC) Calibration keys.

1.
Open the battery compartment lid (end with the lanyard loop). The two white buttons are Increment (INC) and Decrement (DEC) Calibration keys.2. Rinse the electrode in deionized water and then rinse it in the Calibration Standard (6004).

3. Place the electrode in a small container of the Calibration Standard. The cap of the Tester may be used for this. Fill the cap half full. Make sure the sensor is fully immersed.

3. Place the electrode in a small container of the Calibration Standard. The cap of the Tester may be used for this. Fill the cap half full. Make sure the sensor is fully immersed.

3. Place the electrode in a small container of the Calibration Standard. The cap of the Tester may be used for this. Fill the cap half full. Make sure the sensor is fully immersed.

4. Press ON/OFF to turn the meter on. Wait several minutes for the display to stabilize.

5. Press the INC or DEC buttons to adjust the reading to match the Calibration Standard value (4.0 ppt).

6. After 3 seconds without a button press the display will flash three times and then show “ENT”, indicating that the meter has accepted the calibration standard. The meter will then automatically return to the measurement mode.

7. Replace the battery cap.

Replace the battery cap.

TESTING PROCEDURE

1. Remove the electrode cap. Press ON/OFF to turn the meter on.

Remove the electrode cap. Press ON/OFF to turn the meter on.2. Place the electrode into the sample to be tested. Make sure the sensor is fully immersed.3. Wait for the reading to stabilize. The meter will automatically correct for temperature changes but for the best results, the temperature of the sample to be tested and the calibration standard should be the same.

4. Record the reading.

Record the reading.5. Press ON/OFF to turn the meter off. Rinse the electrode in deionized water. Replace the electrode cap.NOTE: The meter will automatically shut off after 8.5 minutes of nonuse.

HOLD FUNCTION

Press the HOLD key to freeze the displayed value. Press HOLD again to release.

CHANGING BATTERIES

1. Open battery compartment lid.

Open battery compartment lid.2. Remove the old batteries and replace with fresh batteries. Note that the polarity of the batteries must match the markings in the batterycompartment.

3. Recalibrate after a battery change.

Recalibrate after a battery change.

METER MAINTENANCE

To improve performance, clean the electrodes by rinsing them in alcohol for 10-15 minutes.Replace all batteries if low battery indicator appears, or if readings are faint or unstable.If drift is experienced, periodically let electrode fully dry and start over.

Replace electrode if needed

This product was added to our catalog on Tuesday 22 May, 2007.
box_bg_r.gif
Reviews Add to Wishlist Quantity:
Related items

Shopping Cart
0 items
Quick Find
 
Use keywords to find the product you are looking for.
Advanced Search
Your Account
Your Email Address
Your Password
Best Sellers
01.Calibration Standard (4.0 Ppt) 120 Ml, LaMotte (6004-J)
02.Calibration Standard for Salt Tracer (120 ml) 6317J
03.Conductivity Standard (12,880 Ppm) 500 Ml, LaMotte (6317L)
04.pH 7.0 Buffer Tablets (100 tablets) LaMotte (3984A-J)
Currencies
Information
Join Our Exciting Mailing List!
Company Info
Shipping and returns
Privacy Notice
Conditions of Use
Contact Us
Salt Chart -All Models
Hours of Operation
Gift Voucher FAQ
Links
Contact Us
Sitemap
Events Calendar
FaqDesk Latest
Are generic cells as good as originals cells?
What should my Total Alkalinty be kept at?
How Much Stabilizer (CYA) do I need to have in my water?
What is the proper salt level for my unit?
Cards We Accept
We take these cards
Tell A Friend
 
Tell someone you know about this product.
Authorize.net

Online Payments


Copyright © 2017 SaltCells.Com

Policies |  Contact Us |  Links |  All Products |  Site map


AutoResponse Plus