X-10 Pro - X-10 Pro - X-10 Pro - - X-10 Pump Switch, 20 Amp, 120 V.-3 Way (XPS3)
TEL: 1-877-733-0259  
 

 

 
Categories
Salt Cell Replacements (Electrodes) ->

Salt Water Chlorinators ->

Salt Water Chlorinators -Spas

Salt Chlorinators-Commericial ->

Accessories-Pool/ Spa/ Landscaping

Automatic Pool Cleaners

Chemical Controllers ->

Chemicals (ALL) ->

Electrical / Electronic Supplies ->
|__Light Bulbs
|__Miscellanious -Electrical
|__PCB Parts
|__Seal Tight/ Liquid Tight
|__Timers
|__Weatherproof Boxes
|__X-10 Pro

Maintenance Equipment

Miscellanious

Parts Section- Salt Chlorinators ->

Parts For All Pools ->

Plumbing Supplies ->

Salt

Test Equipment & Reagents ->

Tools for Installation

Used Or Reconditioned Products

View All Products->

All Products sorted by Categories ->

All Products sorted by Manufacturers ->
Manufacturers
Notifications
NotificationsNotify me of updates to X-10 Pump Switch, 20 Amp, 120 V.-3 Way (XPS3)
Latest products
Electrode (30 Amp) W/Adapter, Quikchlor/Poolpower/Clevachlor * Generic
Electrode (30 Amp) W/Adapter, Quikchlor/Poolpower/Clevachlor * Generic
$695.00
View Latest Additions
Featured Links
Domain Registration and Hosting
Gereral Products for Sale
How to Incorporate Your Business
Swimming Pool Supplies
Who's Online
There currently are 7 guests and 
7 members online.


X-10 Pump Switch, 20 Amp, 120 V.-3 Way (XPS3)
[412-XPS3]

$60.95

 


X-10 Pump Switch, 20 Amp, 120 V.-3 Way (XPS3)

Description: The XPS3 is a mechanical, decorative-style, non-dimming, Single-Pole/3-Way wall switch rated for 20amps. It can handle ON/OFF
loads as follows: Incandescent (120V Standard or Halogen) Bulbs, Low Voltage Transformers, High Wattage Flood Lights, Fluorescent Lighting,
Pumps/Motors and Appliances. The Red LED Indicates its "ON/OFF" status. Its decorative paddle permits local operation of the switch. The X10
Address Code Dials set the House Code and Unit Number and are located behind the paddle.
Specific Requirements: 120VAC, 20amps
Neutral Wire IS required. Ground Wire is not used.
Optional / Supplementary Devices & Modules:
XPSS - Slave Switch is required for existing 3-Way Installations.
XPSP-AL Almond Rocker in Pkg of 10ea. for both XPS3 and XPSS.
XPT1 - Alternate Slave Switch (Transmitter) for existing and new 3-Way/4-way Installations.
XPF - Filter to reduce noise, from load, degrading switch operation.
Non-X10 Contactor - Heavy Load Relay device for High Intensity Discharge (HID) Lighting and other heavy-duty loads.
X10 Protocol:
House Code Dial - Letters A-P (default "A") Unit Number Dial - Numbers 1-16 (default "1")
Each X10 Receiver Module is set to a unique Unit Number or to an identical Unit Number as desired.
Each X10 Controller operating a specific set of Receiver Modules must be set to the same House (Letter) Code as the Receivers they are
controlling.
Responds to ALL LIGHTS ON command
Electrical Protocol:
Nearly all residential homes are wired SPLIT-PHASE. Each 120V Phase is NOT directly connected with the other 120V Phase. If after installation,
an X10 Receiver does not respond to a remote Controller, then check to ensure that the breaker serving the X10 Receiver is on the same phase as
the Controller. If not, the breaker can be changed to the opposite phase. An alternative solution is recommended, to install a Phase Coupler for
improving remote communications throughout the home. See
www.x10pro.com, then select Technical Support and PLC Troubleshooting.
Installation: for Single-Pole operation
1. Turn power OFF at Circuit Breaker
2. Pull-out the existing wall switch from the switch box.
3. Inspect inside the wall switch box for existence of white neutral wire(s) capped-off. If no white neutral wires exist, STOP. You CANNOT use the
XPS3 unless you run a neutral wire to this box.
4. Remove the existing wall switch. Two wires remain protruding out of switch box. One is HOT, the other goes to the light/load. They may be the
same color.
5. With Breaker ON, determine which protruding wire is HOT. Use a voltmeter and measure between ground and each wire individually.
One will read 120V, the other 0V.
6. With Breaker OFF, Connect a white neutral wire to the NEUTRAL Terminal. You may have to tap into a neutral wire bundle with an additional
white wire 6-8" long.
7. Connect the HOT wire to the LINE Terminal, connect the other wire to the LOAD Terminal.
8. No connection is needed at the Control Screw Terminal.
9. Re-check all connections, Turn power ON at Circuit Breaker.
10. Press switch paddle once, you will hear the switch CLICK and the light should turn ON. Press paddle again, you will hear the switch CLICK and
the light should turn OFF.
11. You are now ready to control the switch with an X10 Remote Control Module: desktop, wireless handheld, Security Panel, etc. The default
address is "A1". If you wish to change the code, the Code Dials are behind the paddle. Remove the paddle with a small flat screwdriver applied to
the side of the paddle at the center fulcrum point. Insert screwdriver in small gap space between switch plate and paddle and flip the paddle up
from its side.
12. Mount the Switch in the wall box and attach the switch cover

For more information, please visit this products webpage.
This product was added to our catalog on Friday 03 December, 2010.
Reviews Add to Wishlist Quantity:

Shopping Cart
0 items
Quick Find
 
Use keywords to find the product you are looking for.
Advanced Search
Your Account
Your Email Address
Your Password
Currencies
Information
Join Our Exciting Mailing List!
Company Info
Shipping and returns
Privacy Notice
Conditions of Use
Contact Us
Salt Chart -All Models
Hours of Operation
Gift Voucher FAQ
Links
Contact Us
Sitemap
FaqDesk Latest
Are generic cells as good as originals cells?
What should my Total Alkalinty be kept at?
How Much Stabilizer (CYA) do I need to have in my water?
What is the proper salt level for my unit?
Cards We Accept
We take these cards
Tell A Friend
 
Tell someone you know about this product.


Copyright © 2012 SaltCells.Com

Policies |  Contact Us |  Links |  All Products |  Site map